The gauge is down to zero again. Out comes the filling loop, the system gets topped up, the boiler fires, everyone relaxes. That was the fourth time this month, and we’re still in November.
We get a lot of these in Aldershot. Someone rings us about a boiler losing pressure and by the time we’re through the door they’ve usually convinced themselves the boiler has had it and they’re pricing up a new one. More often than not the boiler is fine. It’s the messenger, not the culprit.
In a sealed heating system, water is either escaping somewhere you can’t see, or the system is letting it out on purpose through a safety valve. No puddle across the kitchen floor. No brown ring appearing on the ceiling. No drama at all, just a gauge that won’t stay where you put it. That’s the awkward bit, because there’s nothing obvious to point at and say “there it is”.
What the pressure gauge tells you when boiler pressure is dropping
As a rough guide, plenty of sealed heating systems sit around 1 to 1.5 bar when cold, but the actual figure depends on the boiler and the size of the system. Check your own manual, or the makers’ help and advice pages if you’re looking it up for your model. Never trust a reading taken with the heating running either, read it cold, first thing, before the boiler has had a chance to fire.
Once the heating comes on, the water expands and the pressure climbs a little. That’s normal and it’s supposed to happen. What matters is the pattern. Low when cold, topped up, then quietly dropping again over the next few days or weeks means water is leaving the system. The speed tells you a lot too. A gauge that falls from 1.2 to nothing overnight is a different animal from one that takes a month to drift down, and we ask about that first.
There is a second pattern worth knowing, and it isn’t a leak at all. If the pressure climbs towards 3 bar as the heating gets hot, then drops back when it cools, and there’s water trickling out of the copper pipe that pokes through the wall outside, the system is dumping water through its safety outlet. That’s usually the expansion vessel not doing its job any more. Same symptom, different repair, and topping the system up will not touch it.
The filling loop habit, and what it can lead to
Topping up feels harmless. The boiler fires, the radiators warm up, everyone gets on with their evening, and the gauge sits there looking innocent for another fortnight. But a filling loop is there for refilling a system after work has been done on it, not as a weekly top-up habit.
Every top-up pushes fresh water in, and fresh water brings dissolved air and oxygen with it. Oxygen in a heating system is what drives corrosion and sludge. You end up with radiators that are hot at the top and cold at the bottom, a boiler that sounds like it’s kettling, valves that stiffen up and don’t shut properly, and eventually more leaks. So the loop doesn’t just hide the original fault, it quietly makes the eventual repair bigger and more expensive. Which is a rubbish deal, really, because the original fault was probably a perished washer in one valve.

There’s also a filling-loop trap. If its valves are left open, or one is passing water when it should be shut, mains water can keep pushing into the heating system. Pressure may rise, water may be discharged through the relief pipe, and the system can waste water without an obvious sign indoors. If you’re unsure whether the loop is closed properly, don’t force a stiff control. It’s better to have it checked.
Where a leak with no puddle can hide

Some leaks are small enough that the water evaporates before it ever leaves a mark. A radiator valve gland is the classic. It weeps a drop at a time round the spindle, and what you find is a green or white crusty bloom on the fitting and a faint smell of damp air in the room. Get a torch down there and look. If the carpet under the valve has a slightly darker patch that never quite dries, that’s your leak, and it’s been going for months.
In the bathroom, look at the tails and connections on the heated towel rail. In older Aldershot houses with microbore pipework, a joint can go under a floor and the water will happily travel along the outside of the pipe or along a joist before it surfaces anywhere useful. Behind plasterboard is another favourite. It comes through somewhere completely unrelated to where it started, which is why people end up decorating a bedroom ceiling when the leak is actually in the airing cupboard.
Around the boiler itself, an automatic air vent can weep very slowly, and a pressure relief valve can pass so gently that you only notice the trickle from the copper pipe outside, running down the wall or dripping onto the patio. A corroded radiator can develop a pinhole that mists out and dries off before it leaves a puddle. Underfloor heating adds a manifold and a lot of concealed pipe to the list.
One thing we can’t do is tell you which of those it is from a photo of the gauge. The gauge tells us what the system is doing. It doesn’t tell us where the water is going.
How we narrow it down without tearing the house apart
The first job is the free one. Look at the pressure relief outlet outside. If that copper pipe is wet, or there’s a green streak down the brick under it, the water is leaving through the safety valve and we can stop looking under floors entirely. Then it’s a slow walk round every visible valve, tail and joint with a torch and a bit of dry kitchen roll. Press the paper against each one. Damp paper means you’ve found something, and you can do that yourself before we arrive if you fancy it.
Next we separate the boiler from the rest of the system by closing the valves on the pipework below it, then watch the gauge on each side. If the boiler side holds and the heating side doesn’t, the leak is in the pipework and there’s no point taking the casing off. If it’s the other way round, it’s on the boiler side and that’s a different job with different rules. It’s a simple test and it saves an awful lot of guessing.
If it holds on both sides, the answers get narrower. Thermal imaging and a damp meter can help us follow the wet line across a floor, though neither is a magic wand. Sometimes we drain and pressure-test a section at a time to bracket the problem down to one room, or one leg of pipe.
Only then do we consider opening up a floor or wall. Sometimes the honest answer is that we’ll need to lift a couple of boards to look, and there will be dust and a hole in the floor for a day. That is still usually a better place to start than lifting the whole floor on a guess and hoping.
For a different sort of hidden leak, have a look at our guide to water leaks on the mains, where there is a wet patch to follow. This article is about the sealed heating circuit, where there may be no visible patch at all.
Three ways the repair can go
If we find one failed joint or valve, we can cut it out and replace it. If the pipe itself has gone, we may be able to re-run a short section along the same route. And if a longer run is corroded, the sensible answer may be to replace it properly rather than patch it in several places and wait for the next weak spot.
Boiler-side work inside the casing is gas work and should only be carried out by a Gas Safe registered engineer. We’ll explain what we’ve found, price the proposed work before it starts, and tell you if topping up and keeping an eye on it is a reasonable option for now.
When it can wait, and when it needs looking at sooner
A slow weep behind a radiator, with pressure holding for weeks, can often be booked in for a planned visit. But if the system won’t hold pressure overnight, there’s water staining on a ceiling below a bathroom, or water is near electrics, it’s worth arranging for someone to look sooner rather than later.
Don’t keep topping up without getting to the bottom of repeated pressure loss. If the cause is small and accessible, finding it early may help avoid extra damage and a larger repair later.
We look after boilers and heating systems in Aldershot, Farnborough, Farnham, Guildford and surrounding areas, and a boiler losing pressure in Aldershot is one of the more common things we get called out to. It’s a good one to get looked at early, while it’s still a valve and not a floor.
Getting a clear answer
We’ll come out, look at the gauge, the valves and the relief pipe, and tell you honestly whether it looks like a valve, a joint, the boiler or something we need to hunt down. You can read more about our work on our plumbing and heating page, or book a visit at a time that works for you.